Description
| Equipment model | Semco SI BCDS 60V 100A 2CH |
| The channel number | 2 CH (Each device has 2 channels.) |
| Communication methods | RJ45 (Network) |
| Charging voltage | DC 0-60V When charging, it can be used to detect and set the voltage range. The maximum voltage is 60V. |
| Discharge voltage | DC 60-3.5V When discharging, the voltage range can be detected and set. The maximum voltage is 60V. |
| Charging current | DC 1-100A When charging, it can be used to detect and set the current range, the maximum current is 100A |
| Discharge current | DC 1-100A When discharging, the current range can be detected and set. The maximum current is 100A. |
| Voltage accuracy | ±(0.05%RD+0.05%FS) |
| Current Accuracy | ±(0.05%RD+0.05%FS) |
| Energy saving efficiency of Charging | 85% |
| Discharge feedback efficiency | 80% |
| Voltage resolution | 1mV the smallest unit used when the device detects or sets the voltage. |
| Voltage stability | ≤0.05% |
| Current resolution | 1mA the smallest unit used when the device
detects or sets the current. |
| Current stability | ≤0.05% |
| Power output range | ≤12KW |
| The input impedance | ≧10 MΩ |
| The input power | AC 380V/220V±10%/ 50Hz |
| Current response time | Current at 30A hardware response time:≤50ms |
Reviews