| Characteristics | Constant current source and constant voltage source, double closed loop structure | ||||
| Input resistance | ≥1MΩ | ||||
|
Voltage |
Range |
Charge | 10mV-5V (tester port) | ||
| Discharge | 1V-5V (tester port), The minimum discharge voltage is related to the line length | ||||
| Precision | ±0.1% of FS, Ambient temperature 15℃-35℃ | ||||
|
Current |
Range |
Charge | 6mA-6A | ||
| Discharge | 6mA-6A | ||||
| Precision | ±0.1% of FS, Ambient temperature 15℃-35℃ | ||||
|
Power |
Single channel | 30W | |||
| Stability | 0.2% of FS | ||||
| Time | ≤10ms (Current response time) | ||||
|
Data record |
Frequency | 1Hz | |||
|
Data recording conditions |
Minimum time interval:1S | ||||
| Minimum voltage interval:1mV | |||||
| Minimum current interval:1mA | |||||
|
Charge |
Charging mode | Constant current charging, constant voltage charging, constant current constant voltage charging, constant power charging | |||
| Cut-off condition | Voltage, current, relative time, capacity, -△V | ||||
|
Discharge |
Discharge mode | Constant current discharge, constant power discharge, constant resistance discharge | |||
| Cut-off condition | Voltage, current, relative time, capacity, -△V | ||||
| Pulse mode Optional | Charge | Constant current mode, constant power mode | |||
| Discharge | Constant current mode, constant power mode | ||||
| Minimum pulse width | Recommended above 5S | ||||
| Cut-off condition | Voltage, relative time | ||||
| Item | Technical parameters | ||||
| DCIR | Optional | Support custom pick points for DCIR calculation | |||
| Cycle | Loop test | 199 commands can be set, 65535 cycles can be set | |||
| Loop nesting | Support 5 levels of loop nesting | ||||
|
Protection |
Software protection |
Support power-down data protection | |||
| Support continuous start (the computer should have UPS power) | |||||
| Overvoltage protection, under voltage protection, capacity protection, overcurrent protection, undercurrent protection | |||||
| Anti-reverse protection | |||||
| Data export method | Excel, PDF | ||||
| cooling method | Wind cooling | ||||
| Equipment noise | ≤60Db | ||||
| Communication | RJ45 network port communication | ||||
| System Requirements | Windows XP and above | ||||
EV battery production, energy storage manufacturing, battery research labs, electronics assembly, and OEM-based fabrication units.
| Specification | Details |
|---|---|
| Product Name | Semco SI-CT 5V 6A 30W Battery Charge & Discharge Tester |
| Equipment Type | Battery Charge & Discharge Tester |
| Voltage Range | 0–5 V |
| Maximum Current | 6 A |
| Output Power | 30 W per Channel |
| Charge Modes | Constant Current (CC), Constant Voltage (CV), CC-CV |
| Discharge Modes | Constant Current (CD) |
| Measurement Accuracy | High-precision voltage & current measurement |
| Communication | Ethernet / PC Software |
| Software Features | Real-time Monitoring, Cycle Testing, Capacity Analysis, Curve Display & Data Logging |
| Cooling System | Forced-Air Cooling |
| Supported Battery Types | Cylindrical, Prismatic & Pouch Lithium-ion Cells |
| Applications | Battery Performance Testing, Capacity Grading & Quality Validation |