Battery Charge Discharge Tester ( Semco SI BCDS 34V 30A 8CH )

Multi-Channel Battery Charge–Discharge Tester- Eight-channel 34 V / 30 A / 460 W per channel tester for lead-acid and lithium batteries, featuring CC/CV charging, constant current discharge, high-accuracy voltage/current control, and independent channel control. Supports 1–5000 cycle life tests, temperature monitoring, rich protections (reverse, OVP, OTP, short-circuit, power-down), and TCP/IP PC software with Excel report export for lab and production QA.

Semco SI BCDS 34V 30A 8CH – 8-Channel 34V / 30A Charge–Discharge Platform for Lead-Acid & Lithium Packs

The Semco SI BCDS 34V 30A 8CH is an 8-channel storage battery charge–discharge tester designed for lead-acid and lithium batteries in R&D, QC and small-batch production. It operates from AC 220 V ±10%, 50/60 Hz, with no-load 100 W and full-load 4100 W input. Each channel delivers up to 460 W and is independently controlled, allowing simultaneous testing of 8 batteries with separate profiles and logging.

On the voltage side, the system supports 7–34 V CC/CV charging with ±0.05 V tolerance and 2–34 V discharge cut-off with ±0.03 V tolerance. Current capability ranges from 0.5–20 A charge and 0.5–30 A discharge, with ±0.1 A (charge) and ±0.03 A (discharge) accuracy and 0.1 A minimum charge cut-off current. A 4-wire sampling arrangement improves measurement accuracy and pack voltage control.

Key Technical Snapshot
Parameter Specification
Model Semco SI BCDS 34V 30A 8CH
Channels 8 (independent control)
Voltage range (charge) 7–34 V (CC/CV)
Voltage range (discharge) 2–34 V
Max charge / discharge I 20 A / 30 A
Max power per channel 460 W
Cycle index 1–5000
Temp range (monitoring) 0–65 °C
Communication TCP/IP (LAN), PC software, Excel logs

The system supports constant current & constant voltage charge and constant current discharge, with flexible cut-off by voltage, current, time, capacity, temperature and temperature rise rate. It includes power-down data protection, reverse connection, over-temperature, over-voltage and short-circuit protection, meeting IP20 and AC 1000 V / 2 min inter-channel insulation. Operating conditions are 0–40 °C, ≤70% RH, with noise <76 dB. Host software (Windows XP / 7 / 8 / 10) communicates via TCP/IP LAN, storing data on a server (>100 GB) and exporting Excel test reports. The compact 840 × 350 × 179 mm unit with clip fixtures is ideal for benchtop multi-pack cycle, capacity and performance testing.

Inquire Now

Description

Semco SI BCDS 34V 30A 8CH , a high-performance Battery Charge Discharge Tester designed for precise testing of Lead-acid and Lithium Batteries. This advanced system ensures accurate performance evaluation, making it ideal for battery manufacturers, research labs, and testing facilities.

Reviews

There are no reviews yet.

Be the first to review “Battery Charge Discharge Tester ( Semco SI BCDS 34V 30A 8CH )”

Your email address will not be published. Required fields are marked *

FAQs

What does SEMCO Infratech specialize in?
SEMCO Infratech is a division of the Semco Group, specializing in the design, manufacture, and distribution of lithium‑ion cell processing, battery pack assembly machinery, and battery testing equipment. Their turnkey solutions include automated and semi‑automated assembly lines for cylindrical, prismatic, and pouch cells